Add To Cart Request Quote

Item # 1262-5000, 1262 Reducing Regulators

List Price $561.00

    border="0" Printable Page  
    Email Email This Page  
    Save To Favorites Save To Favorites
  

  • Reducing Regulator
  • Dome Loaded Amplifying Regulator
  • 1/4 in. NPT
  • 44:1 amplification
  • 0 to 5000 psi outlet





 Specifications   

Series Designation

1262 Series

Type

Reducing Regulator

Hand Loaded/Operated or Dome/Air Operated

Dome Loaded

Maximum Rated Pressure

6000 psi

Outlet Pressure Setting Range/Adjustment Range

0-5000 psi

Outlet Pressure Rating

6000 psi

Maximum Control or Dome Pressure

120 psi

Inlet Port Size

2 ea 1/4 in. FNPT (One Inlet, One Gauge)

Outlet Port Size

2 ea 1/4 in. FNPT (One Outlet, One Gauge)

Flow Coefficient (Cv)

0.05 (equals 0.07 in. orifice)

Outlet Pressure Variations with Inlet Pressure Variations

View
50 psi rise/1000 psi drop at inlet

Leakage

Bubble Tight

Control Port Size

1/4 in. FNPT + 1/4 in. FNPT vent fitting

Weight

970 g

Overall Length

4.25 Inch

Round Diameter

3 Inch

Minimum Temperature

-15 ºF

Body Material

Anodized Aluminum

Internal Materials

Anodized Aluminum
Brass

Stainless

Seal Materials

Buna-N
Kel-F

Viton

Repair Kit/Service Items

1262-5000-22


 DOWNLOADS 

Technical Bulletin for 1262 Reducing Regulators
(DOC, 110KB)

Model 1262 Regulator Operations & Maintenance Manual
(PDF, 13KB)



 Repair Kit for 1262-5000 Regulator 


Repair Kits
1262-5000-22
Repair Kit for 1262-5000 Regulator
$88.00